HUBER+SUHNER SHV (Safe High Voltage) connectors provide more secure handling: center contacts are well recessed to prevent shock hazards in unmated condition. All inner contacts are fully captivated and will withstand axial forces of 100 N minimum. When mating a connector pair the outer conductor contact is made prior to the inner conductor contacts.
SHV connectors are suitable for all high voltage applications up to 5 kV DC or 3.5 kV rms. These connectors are typically used in nuclear instruments or test and measurement equipment. Voltages are valid for both, the mated and the unmated condition.
Mechanical data
Flange dimention |
Type square flange |
17.5 X 17.5 mm |
Tab Style |
|
solder end |
Terminal Dimension D1 |
1.70 mm |
Terminal Dimension L1 |
|
21.30 mm |
Terminal Dimension D2 |
|
6 mm |
Terminal Dimension L2 |
|
17.20 mm |
Electrical data
Impendance |
50 Ω |
Max. Interface frequency |
≤ 0.30 GHz |
Environmental and general data
Operating Temp min |
-65 °C |
Operating Temp max |
165 °C |
Weight |
0.0144 kg |
Number of Matings |
500 |
Material data
2002/95/EC (RoHS) |
compliant |
Piece part |
Base material |
Plating |
Centre Contact Material |
Brass |
Gold Plating (Nickel underplated) |
Outer Contact Material |
Brass |
SUCOPLATE (R) Plating |
Insulator Material |
PFA / PTFE |
|
Body Material |
Brass |
SUCOPLATE (R) Plating
|