Sucofeed Aluminium Feeder Cables 1 1-4 and 1 5-8 light weight

SUCOFEED aluminium – corrugated cables


HUBER+SUHNER SUCOFEED_LW is a foam dielectric corrugated coaxial cable designed with an aluminium outer conductor and a copper clad inner conductor. This low weight SUCOFEED_ LW cables are a cost efficient alternative to the copper transmission lines. The performance of the aluminium cables is equivalent to the copper transmission cables.

 

Applications

• Feeder lines to connect antennas with cellular base stations

• Connectivity solution for distributed antenna systems (DAS) 

 

Features

• Light weight

• Electrical performance equal to copper cables

• HUBER+SUHNER connectors are fully compatible with aluminium and copper cables

• Available with UV-resistant polyethylene jackets, flame-retardant jackets on request

 


Sucofeed Aluminium Feeder Cables 1 1/4" and 1 5/8" light weight

Cable design

 

SUCOFEED_1-1/4_LW

SUCOFEED_1-5/8_LW_LA

Dimension

1-1/4"

1-5/8" low attenuation

Cable group

M32

M43

Jacket version

PE

PE

Inner conductor

(Ø in mm)

13.10

17.60

Dielectric

(Ø in mm)

32.00

41.50

Outer conductor

(Ø in mm)

36.00

46.50

Jacket

(Ø in mm)

39.20

50.30

 

Electrical data

Typ. operating frequency

(GHz)

≤ 3.60

≤ 2.75

Impedance

(Ω)

50 ± 1

50 ± 1

Capacitance

(pF/m)

75

74

Relative signal propagation

(%)

88

89

Signal delay

(ns/m)

3.8

3.8

Max. operating voltage

(kVrms)

4.2

5.6

Typ. attenuation @ 1 GHz

(dB/100 m)

3.20

2.48

Typ. attenuation @ 2 GHz

(dB/100 m)

4.70

3.69

Typ. attenuation @ 2.2 GHz

(dB/100 m)

4.97

3.91

Typ. attenuation @ 2.5 GHz

(dB/100 m)

5.34

4.21

Typ. attenuation @ 2.7 GHz

(dB/100 m)

5.58

4.41

Max. power @ 1 GHz (40 °C)

(kW)

≤ 3.350

≤ 4.100

Max. power @ 2 GHz (40 °C)

(kW)

≤ 2.369

≤ 2.899

Max. power @ 2.2 GHz (40 °C)

(kW)

≤ 2.259

≤ 2.764

Max. power @ 2.5 GHz (40 °C)

(kW)

≤ 2.119

≤ 2.593

Max. power @ 2.7 GHz (40 °C)

(kW)

≤ 2.039

≤ 2.690

 

General data

Temp. range operating

(°C)

–55 / +85

–55 / +85

Temp. range installation

(°C)

–40 / +60

–40 / +60

Typ. weight

(kg/100 m)

≤ 65

≤ 99

Min. bending radius

(mm)

200 / 400

280 / 500