Heating Thermostat , Elektra ETO2
Detailed description
|
ELEKTRA ETV
DIN bus installation. Temperature controller with temperature sensor. Compact dimensions (2 modules). LED on for system operation.
|
|
ELEKTRA ETV-1991 thermostat |
ELEKTRA ETN4
DIN bus installation. Temperature controller supporting two temperature sensors, including a limiting one. Large backlit display presents the operating parameters of the controller. Adjustable hysteresis allows to define precision of the temperature measurements. Equipped with the on/off switch.
|
|
ELEKTRA ETN4-1999 thermostat |
ELEKTRA ETI
DIN bus installation.. Temperature controller with temperature sensor. Adjustable hysteresis allowing to assess in detail temperature measurement precision. Compact dimensions (2 modules). LED on for system operation. In special cases (greasy pipes or temporary in-pipe temperature exceeding +70°C e.g. while flushing or washing),
|
|
ELEKTRA ETI-1544 thermostat
|
ELEKTRA ETI-1522 temperature controller is recommended, which features especially designed sensor with safe operation temperature range from -40°C to +120°C.
|
|
ELEKTRA ETI-1522 thermostat ((temperature sensor with installation opening) |
UTR 60-PRO
Switchboard mounting. Temperature controller especially designed for ELEKTRA SelfTec PRO self-regulating cable pipe heating systems. Features temperature sensor for on-pipe installation, with safe operation temperature range for -40°C to +120°C. Adjustable hysteresis allowing to assess in detail temperature measurement precision. LEDs on for system operation.
|
|
ELEKTRA UTR 60-1544 thermostat |
|
|
Istıma Thermostat , Elektra ETO2
|
Power supply |
120/230 V ~ 50/60 Hz |
Built-in transformer |
24VAC, 6VA |
Max. load |
3x16A, 230 V ~ 50/60 Hz (potential free relays) |
Installation |
DIN-rail or surface mounting |
Temperature range |
0°C ÷ +5°C |
Difference/Hysteresis |
0.3K Controller cover protection (surface mounting) IP 21 |
Work signalization |
LED |
Temperature sensor calibration |
potentiometer |
Dimensions (H x W x D) |
90 x 156 x 45 mm |
Modules |
9 |
|
`
|
Ground temperature and moisture sensor
ETOG-56T and an installation tube ETOK-T
(for soil, concrete flagstones,
paving cobbles), used for heating
control of drives,
traffic routes,
etc.
|
ELEKTRA ETO2 controller
(max. load up to 3 x 16 A), suitable for servicing
one or two zones:
two different roof and gutter zones or
two outdoor areas (e.g. drive and stairs).
|
|
Moisture sensor ETOR-55
(for gutter bottom
installation) used for
heating control of roofs
and gutters.
|
Air temperature
sensor ETF-744
(for outdoor installation) and
|
Downloads